search cancel

Test Connection fails for Autosys scheduler Autosys1136SP5

book

Article ID: 244328

calendar_today

Updated On:

Products

Automic Automation Intelligence

Issue/Introduction

Test Connection fails for Autosys scheduler Autosys1136SP5

 WARN  [RunCycle] Jammer failed for scheduler: Autosys: com.termalabs.common.ConnectionFailureException: com.termalabs.common.ConnectionFailureException: com.termalabs.common.datastore.SessionUnavailableException: Could not create a session
 at com.termalabs.server.hibernate.autosys.AutosysDataFactoryImpl.getDataSource(AutosysDataFactoryImpl.java:51)
 at com.termalabs.server.autosys.jammer.AutosysNewJammer.processRuns(AutosysNewJammer.java:307)
 at com.termalabs.server.system.RunCycle$JammerRunner.runJammer(RunCycle.java:925)
 at com.termalabs.server.system.RunCycle$JammerRunner.run(RunCycle.java:907)
 at com.termalabs.server.system.RunCycle.compute(RunCycle.java:279)
 at com.termalabs.server.system.CommonJammerSequence.runCycle(CommonJammerSequence.java:225)
 at com.termalabs.server.system.CommonJammerSequence.runJammerSequence(CommonJammerSequence.java:158)
 at com.termalabs.server.system.JammerSequence.run(JammerSequence.java:141)
 at java.util.concurrent.Executors$RunnableAdapter.call(Unknown Source)
 at java.util.concurrent.FutureTask.run(Unknown Source)
 at java.util.concurrent.ThreadPoolExecutor.runWorker(Unknown Source)
 at java.util.concurrent.ThreadPoolExecutor$Worker.run(Unknown Source)
 at java.lang.Thread.run(Unknown Source)
Caused by: com.termalabs.common.ConnectionFailureException: com.termalabs.common.datastore.SessionUnavailableException: Could not create a session
 at com.termalabs.common.connection.hibernate.autosys.AutosysDataFactoryImplCommon.getDataSource(AutosysDataFactoryImplCommon.java:56)
 ... 12 in common

Environment

Release : 6.0

Component : AUTOMIC AUTOMATION INTELLIGENCE INTEGRATION FOR AUTOSYS

Resolution

1. Open the AAI thick client and go to the Admin->Schedulers tab.

2. Edit the affected scheduler and select "Test Connection" and see if it fails.

3. If it fails it is an indication that there is something wrong with your Autosys database connection details, possibly an expired password.

4. Verify the DB connection details with your Autosys DBA and make the necessary changes and save the changes.