Did a new install of Date Simulator release 2.0 in CICS 5.6. When CICS 5.6 is started the Date Simulator PLT load module WARPCTIM abends with an AEY9. The Date Simulator cumulative fix level TF1D335 currently being used works in CICS 5.4.
Z/OS
CICS 5.6
Date Simulator r 2.0 cumulative fix level does not support CICS 5.6. CICS 5.6 is supported by Date Simulator cumulative fix level TF1D338.
Apply cumulative fix level TF1D338. Since Date simulator is not under SMP control the client can browse the Date Simulator CICS load modules below to verify the link edit time and date stamps.
The time and date stamps listed below are shipped with cumulative fix TF1D338.
Below are Date Simulator CICS PPT's..
DEFINE PROGRAM(WARPCTIM) GROUP(TWARP)
WARPCTIM V200 04/09/14 13.47
DEFINE PROGRAM(WARPCIC2) GROUP(TWARP)
WARPCIC2 V200 05/19/15 02.55
DEFINE PROGRAM(WARPCIC4) GROUP(TWARP)
WARPCIC4 V200 10/17/14 12.08
DEFINE PROGRAM(TIMECICS) GROUP(TWARP)
TIMECICS 02/02/12
DEFINE PROGRAM(WARPCICS) GROUP(TWARP)
WARPCICS V200 09/21/20 03.15