High Experience Load on Monitoring Points
search cancel

High Experience Load on Monitoring Points

book

Article ID: 243498

calendar_today

Updated On:

Products

AppNeta

Issue/Introduction


We are seeing high experience load on a few monitoring points could you please suggest a solution for this.

 

Environment


Component : AppNeta Default

Cause


The combined transaction times for all the WebPaths on the individual monitoring points was approaching
   the poll interval time. ( ex 5-minute poll interval, the combined webpath transactions were 260 - 305secs). This means
   that the tests are continually running.






Note: Smaller appliances like the m35 are only capable of running 1 test at a time so they run sequentially.

 

Resolution


Investigate the Webpath execution to try and locate which steps are taking a long time to execute and see if the problematic steps can
   be adjusted to reduce execution time (potentially on the target side or the mp actions).

Additional Information


AppNeta Related Documentation: Experience Load