High Experience Load on Monitoring Points
search cancel

High Experience Load on Monitoring Points

book

Article ID: 243498

calendar_today

Updated On:

Products

AppNeta

Issue/Introduction


We are seeing high experience load on a few monitoring points could you please suggest a solution for this.

Environment


Component : AppNeta Default

Cause


The combined transaction times for all the WebPaths on the individual monitoring points was approaching
   the poll interval time. ( ex 5-minute poll interval, the combined webpath transactions were 260 - 305secs). This means
   that the tests are continually running.






Note: Smaller appliances like the m35 are only capable of running 1 test at a time so they run sequentially.

 

Resolution


Investigate the Webpath execution to try and locate which steps are taking a long time to execute and see if the problematic steps can
   be adjusted to reduce execution time (potentially on the target side or the mp actions).