TPX comes with default messages. To customize the messages, follow the procedure described below.
TPX issues various one-line messages to panels. The messages are stored in the CB0VPxxx library, member TxxMSGL, where xx
For example, the English messages are in the CB0VPENU library, in member TENMSGL.
One-line messages (marked in RED) can be modified, but the message prefix and number (Marked in BLUE) must remain the same.
Example:
IENS004A PASSWORD/PASSWORD PHRASE OMITTED OR IS NOT CORRECT.
IENS004B TRY AGAIN OR HIT 'CLEAR' TO CANCEL.
After modifying the messages, restart TPX to put the changes into effect.
NOTE:
Apply the following PTFs to enable TxxMSGL changes to take effect after reload without the need to cycle the TPX started task:
The information above can be found at: Modify One-Line Messages