CEM's CEMCSRVR STC abends at startup with SA03.
Release : 6.0
Component : COMPLIANCE EVENT MANAGER
The platform's TCPIP stack and or ENF task were not fully initialized prior to the startup CEM's CEMCSRVR task.
It was determined that Automation start up delays may have caused the initial abends. It is imperative that the TCPIP address and the ENF task (Protocol=Both as defined in CEM's CUSTOM.PARMLIB(CEMESPRM) member) are fully initialized before starting the CEMCSRVR task.