OPSMVS ABEND - OPS0021U abend error X'806' AT OPINAS+X'000044CA' 
search cancel

OPSMVS ABEND - OPS0021U abend error X'806' AT OPINAS+X'000044CA' 

book

Article ID: 242884

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

The failure message:

OPS0021U abend error X'806' AT OPINAS+X'000044CA' 

OPS/MVS fails to initialize.

The error occurred after applying maintenance to another product.

Environment

Release : 14.0

Component : OPS/MVS

Cause

OPSMVS could not locate module CCSOPEXM from the (Common Services) ccshlq.CAW0PLD load dataset.

An error in SYS1.PARMLIB prevented the CCS CAW0PLD dataset being added to the LINKLIST.

Resolution

Ensure that SYS1.PARMLIB correctly adds CCS dataset ccshlq.CAW0PLD to the LINKLIST.

Additional Information