Using MacKinney Batch to CICS in order to open/close Datacom CICS URTs, but the job gets RC 8 due to error messages like the following ones:
DBLC OPEN=086
MBCE137-COMMAND DBLC OPEN=086 WAS UNSUCCESSFUL RC(76)
DBLC OPEN=086
DBLC OPEN=087
MBCE137-COMMAND DBLC OPEN=087 WAS UNSUCCESSFUL RC(76)
DBLC OPEN=087
Release : 15.1
Component : DATACOM CICS SERVICES
Datacom Return Code 76 it's a generic OPEN ERROR, so check the MUF joblog for any specific error.
At the same date/time MBCBATCH job gets the errors:
MBCE137-COMMAND DBLC OPEN=086 WAS UNSUCCESSFUL RC(76)
MBCE137-COMMAND DBLC OPEN=087 WAS UNSUCCESSFUL RC(76)
on MUF joblog these RACF messages were displayed:
02.14.08 STC16575 ICH408I USER(<muf.userid> ) GROUP(STCGRP ) NAME(DB MUF ) 422
422 <area.dataset> CL(DATASET ) VOL(nnnnn)
422 INSUFFICIENT ACCESS AUTHORITY
422 FROM hlq.*.** (G)
422 ACCESS INTENT(UPDATE ) ACCESS ALLOWED(NONE )
So <muf.userid> is not authorized to open some datasets.