Abend S0C4 and IEC999I after upgrade to z/OS 2.5
search cancel

Abend S0C4 and IEC999I after upgrade to z/OS 2.5

book

Article ID: 242754

calendar_today

Updated On:

Products

Allocate DASD Space and Placement

Issue/Introduction

Operating system upgraded from Z/OS 2.3 to Z/OS 2.5.

When executing a job with CA-Allocate active, an abend occurs with code S0C4 and message IEC999I.

PTF LU02555 was successfully applied before the upgrade.

IEC999I IFG0554P,jobname,stepname

SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011

  NO ACTIVE MODULE FOUND
  NAME=UNKNOWN

Environment

Release : 12.5

Component : Allocate DASD Space and Placement

Resolution

If LU02555 is already applied, check if SO14967 required for z/OS 2.4 compatibility is applied.

It is also required for z/OS 2.5.

S0C4s can occur if SO14967 is not applied.

 

 

Additional Information

See the Allocate compatibility page.

See article 227625 -  z/OS 2.5 compatibility requirements for CA-Allocate V12.5