When starting Intertest CICS release 11 in CICS using the CNTL=START command module IN25CO6I abends with an S0C4 abend.
The CICS log contains the following message
DFHAP0001 CICSPSA An abend (code 0C4/AKEA) has occurred at offset X'FFFFFFFF' in module IN25CO6I.
Z/OS
CICS
The fix SO15051 that introduced load module IN25CO6I to Intertest CICS release 11 has been applied in error. The clients SMP report shows several of the client Intertest r 11 fixes applied in error.
The SMP report of the Intertest CICS r 11 CSI shows the status of fix SO15051.
SO15051 TYPE = PTF
DESCRIPTION = BREAKPOINT MALFUNCTION IN SUBPROGRAMS + COB 5.1+DYN CALLS
STATUS = REC BYP APP ERR
FMID = CCSAB00
JCLIN = YES
DATE/TIME REC = 22.126 08:52:04
INS = 22.126 09:55:23
SOURCEID = CAP2011
PRE VER(001) = RO97433 RO99725 SO04586 SO05172 SO06137 SO06273 SO07319 SO13493
SUPING VER(001) = SO14145 ST14145 ST14647 ST15051
IFREQ = SO15050
MOD = IN25CO6I IN25DHOK IN66GLU1 IN66HOOK IN67GLU1 IN67HOOK IN68GLU1 IN68HOOK IN69GLU1
IN69HOOK IN70GLU1 IN70HOOK IN71GLU1 IN71HOOK IN72GLU1 IN72HOOK IN73GLU1 IN73HOOK
The client needs to reinstall Intertest CICS r 11 or try an apply REDO to correct all the r 11 fixes that are applied in error.