We have deployed hp3par probe and created profile for the device but we are getting multiple alarms in alarm console as below.
Release : 20.3
Component : UIM- HP_3PAR
The hp_3par probe collects data through a combination of standard SMI-S CIM API and 3PAR command line (CLI) option. For a few metrics, data is collected using CLI commands while for other metrics, the SMI-S provider is used.
In order for the CLI commands to work, the ssh port (22) must also be opened between the robot where the hp_3par probe is deployed and the monitored storage device. You can verify that this port is opened executing the following telnet command from the robot where the hp_3par probe is deployed:
telnet <IP address of the monitored HP 3PAR storage device> 22
If this connection fails, then the probe will not be able to collect all available metrics from this device.