Issue/Introduction

Trying create a ALERT  from DCI ISPF application, but the following message is returned:  

 ---------------------------------------- CA DCI ----------------------------------------
                                               Alert Definition 

--------------------------------------------------------------------------------------------- 
ID                       IDxx 
Type                   CAPLIMIT                                       
Policy                 POLICYyy                            
EMail-ID             [email protected]
CPCID                IDzz   
GRP/SYS           ________                                
Command ===> __________________________________      
  F1=Help     F2=Split    F3=Exit     F7=Up           
  F8=Down     F9=Swap    F12=Cancel   
____________________________________
I                                                                       I
I  % Limit is missing. Please enter a % Limit. I
I___________________________________ I          

 The Application asks for a parameter that is not in the panel (%Limit)                                                     

Environment

Release : 2.0

Component : DYNAMIC CAPACITY INTELLIGENCE

Cause

PFSHOW was set to ON which overlaid the display for % Alerts and MSU Limits below the settings for GRP/SYS and COMMAND

Resolution

Set PFSHOW to OFF.    

Additional Information

Reference the DCI r 2.0 documentation for the settings for DEFINE ALERTS  there are no PFKEY assignments on the bottom of the display.