search cancel

rsp probe crashing with username password combination that exceeds ~40 characters

book

Article ID: 241602

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

We are having trouble with the rsp probe crashing on newly created UIM hubs.  The probe is running, but once we try to add a server in to monitor, the probe crashes.  At some points, we can do a discovery, some of the parameters load, but not all, then we try a rediscovery and it fails.  Eventually, the rsp probe crashes.

Cause

Username password combo is greater than about 40 characters in length.

Environment

Release : 20.4

Component : UIM - RSP

Resolution

Resolved with rsp-5.51-T1.

Attachments

rsp-5.51-T1_1658765054564.zip get_app