search cancel

getting CA-7.1023 - Master Station Message Routing error

book

Article ID: 241067

calendar_today

Updated On:

Products

CA 7 Workload Automation

Issue/Introduction

 Hi,

  We are getting these message -

CA-7.1023 - Master Station Message Routing error                           
CA-7.1024  SEND: RC(08) REASON(20 08 00 00) Node: #06E2     CAI_OPR_DAEMON 
CA-7.1025 FDBK: NETWORK PATH TO REMOTE CCI NOT ACTIVE    

Please advise

 

 

 

               

Environment

Release : 12.0

Release:  12.1

Component :  CA 7

Resolution

The 06E2 is the CCI node.  Probably a mainframe LPAR that does not have an EVENT MANAGER..   You need to remove it from the top of the  MSGRCNTL

dataset if you do not run the event manager or GTS/ECHO on that lpar. Otherwise, it not a problem and will not cause a problem, but you will continue to get

the message, to which there is no action from the customer end.

Additional Information

https://techdocs.broadcom.com/us/en/ca-mainframe-software/automation/ca-workload-automation-ca-7-edition/12-1/search.html?q=CA-7.1023&page=1