MTC-M error accessing LPAR via HTTP: "End of data during tcp/ip handshaking"
search cancel

MTC-M error accessing LPAR via HTTP: "End of data during tcp/ip handshaking"

book

Article ID: 240867

calendar_today

Updated On:

Products

Vantage Storage Resource Manager

Issue/Introduction

Vantage 14.1 was successfully installed and customized, but when I access Vantage using the MTC-M Client via HTTP,  I get the following error message in MTC-M: 

"End of data during tcp/ip handshaking"

The Web Client STC also shows the following error: 

31 Apr 2021 13:55:54,820 ERROR http-nio-8080-exec-9 RPCMon:72 ERROR: RPC failed for the method 'connectHostById'. THREAD: http-nio-8
080-exec-9                                                                     
com.ca.vantage.impl.ews.exception.EWSException: End of data during tcp/ip handshaking 
.at com.ca.vantage.impl.ews.conn.Connection.handshake(Connection.java:205) 
.at com.ca.vantage.impl.ews.conn.Connection.<init>(Connection.java:143) 

etc. etc.

Environment

Release : 14.0

Component : Vantage Storage Resource Manager

Cause

The incorrect Port number is being used in the MTC-M Host definition.

Resolution

The problem is resolved by correcting the Port number used in the MTC-M Host definition so that it matches the Port number of the base Vantage task.