Issue/Introduction

DR exercise OPSMAIN abended with the following message.

OPS3000S ESTAE LEVEL 1 PROGRAM CHECK CODE=102 TIME=16:26:16 SEQ=0 CPU=00 ASID=0026 (010D 010D) 

ESPSTRT - JOB=AOSEMAIL (57625) APPL= OSD=2022-04-27                            
OPS3000S ESTAE LEVEL 1 PROGRAM CHECK CODE=102 TIME=16:26:16 SEQ=0 CPU=00 ASID=0
OPS3006I PSW AT TIME OF ERROR 478C1000 815FCC72 ILC 4 INTC 11 RSCD 0000000C    
OPS3007I CURRENT ROUTINE NAME=OPSMMG ADDRESS=2235F000 OFFSET=000065EE          
OPS3008I GPR  0-3  00000088 00F70880 00000080 00000010                         
OPS3008I GPR  4-7  00000000 00001960 24260E38 00F70880                         
OPS3008I GPR  8-11 015FE748 80000000 7FFFAC40 7FFFAC40                         
OPS3008I GPR 12-15 00001960 80C00026 815FC67E 00000000                         
OPS3008I AR  0-3  00000000 00000000 00000000 00000000                          
OPS3008I AR  4-7  00000000 00000000 00000000 00000000                          
OPS3008I AR  8-11 00000000 00000000 00000000 00000000                          
OPS3008I AR 12-15 00000000 00000000 00000000 00000000                          
OPS3009I ABENDING LOCATION  OPSMMG+X'65EE'                                     
OPS3009I UNKNOWN  CALLED BY OPSMMG+UNKNOWN                                     
OPS3009I OPSMMG   CALLED BY OPEPEX+X'D7A2'                                     
OPS3259S Product shutdown started due to subtask failure - X'000004'           
OPS9998I Health Check CCS services terminated                                  
OPS9998I OPMTCANT: Notifications disabled                                      
OPS5006O Notify subtask terminating                                            
IST413I VTAM DUMPING FOR JOB OPSMAIN  STEP OPSMAIN                             

It results in an S102 abend in module OPSMMG

Environment

OPSMVS - Release : 13.5 14.0
Z/OS 2.4

Cause

At DR site OPSMVS failing.  Root cause is:
The End Of Task exit that runs the EPI cleanup code was not called when
a REXX running in an OSF server ended.

Resolution

PTFs for each release:

Release       Sysmod 
  13.5        LU03738
  14.0        LU03721 superseded by LU11034