DR exercise OPSMAIN abended with the following message.
OPS3000S ESTAE LEVEL 1 PROGRAM CHECK CODE=102 TIME=16:26:16 SEQ=0 CPU=00 ASID=0026 (010D 010D)
ESPSTRT - JOB=AOSEMAIL (57625) APPL= OSD=2022-04-27
OPS3000S ESTAE LEVEL 1 PROGRAM CHECK CODE=102 TIME=16:26:16 SEQ=0 CPU=00 ASID=0
OPS3006I PSW AT TIME OF ERROR 478C1000 815FCC72 ILC 4 INTC 11 RSCD 0000000C
OPS3007I CURRENT ROUTINE NAME=OPSMMG ADDRESS=2235F000 OFFSET=000065EE
OPS3008I GPR 0-3 00000088 00F70880 00000080 00000010
OPS3008I GPR 4-7 00000000 00001960 24260E38 00F70880
OPS3008I GPR 8-11 015FE748 80000000 7FFFAC40 7FFFAC40
OPS3008I GPR 12-15 00001960 80C00026 815FC67E 00000000
OPS3008I AR 0-3 00000000 00000000 00000000 00000000
OPS3008I AR 4-7 00000000 00000000 00000000 00000000
OPS3008I AR 8-11 00000000 00000000 00000000 00000000
OPS3008I AR 12-15 00000000 00000000 00000000 00000000
OPS3009I ABENDING LOCATION OPSMMG+X'65EE'
OPS3009I UNKNOWN CALLED BY OPSMMG+UNKNOWN
OPS3009I OPSMMG CALLED BY OPEPEX+X'D7A2'
OPS3259S Product shutdown started due to subtask failure - X'000004'
OPS9998I Health Check CCS services terminated
OPS9998I OPMTCANT: Notifications disabled
OPS5006O Notify subtask terminating
IST413I VTAM DUMPING FOR JOB OPSMAIN STEP OPSMAIN
It results in an S102 abend in module OPSMMG
OPSMVS - Release : 13.5 14.0
Z/OS 2.4
At DR site OPSMVS failing. Root cause is:
The End Of Task exit that runs the EPI cleanup code was not called when
a REXX running in an OSF server ended.
PTFs for each release:
Release Sysmod
13.5 LU03738
14.0 LU03721 superseded by LU11034