OneClick is showing an inaccurate condition with condition value of critical when there are no alarms present
search cancel

OneClick is showing an inaccurate condition with condition value of critical when there are no alarms present

book

Article ID: 240474

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

Even though we're able to ping and poll the device successfully, the condition of the device appears to be critical. There's no events or alarms for this device. Could you please check and advice ?

Environment

Release : 10.x, 21.2.x

Component : Spectrum Alarms

Cause

Rare instance that Condition value is not updated correctly in Spectrum

Resolution

Setting the device into maintenance mode and waiting 1 poll cycle and then removing the device from maintenance will force the condition attribute to be recalculated which should resolve the problem.  If not please provide an export of events for the device to include the event type for the maximum 45 days and open an issue with Support for further investigations.