Hello.
Lately we have been getting this HC alert in out environment.....What's unusual is that the TMC and AUDIT datasets are on different volumes:
1************************************************************************
* *
* HZSU002I Log stream: HZS.HEALTH.CHECKER.HISTORY *
* *
* Filter: CHECK(CA_1,CA1_TMC_AUDIT_PLACEMENT) *
* Filter: SYSNAME(1234) *
* Filter: Only checks with exception(s) *
* *
************************************************************************
************************************************************************
* *
* Start: CHECK(CA_1,CA1_TMC_AUDIT_PLACEMENT) *
* Sysplex: PLEX System: 1234 *
* *
************************************************************************
CHECK(CA_1,CA1_TMC_AUDIT_PLACEMENT)
SYSPLEX: PLEX SYSTEM: 1234
CHECK DATE: 20201208 CHECK SEVERITY: MEDIUM-DYNAMIC
Single Point of Failure Analysis for TMC and Audit
File Data Set Name Volume
----- -------------------------------------------- ------
TMC TMS.TMC PACK01
Audit TMS.AUDIT PACK02
IOSPF352I Volumes PACK01 (9876) with
TMS.TMC and PACK02 (8765) with
TMS.AUDIT share the same physical control unit.
TMC and Audit are on the same control unit.
Release : 14.0
Component : CA 1 Tape Management
Please note that this problem has been reported before. PTF SO16131 introduced extra Health Checking for SPOF (Single Point of Failure).
Since then, another PTF has been created to provide options if you want this condition checked. This PTF is LU03509. You can download it via this link.
Alternative you could move the TMC to a different control unit. You can do this dynamically with TMSXTENT utility. You cannot move the Audit file without stopping tape processing.