PTF LU04125 giving GIM37903E during apply check
search cancel

PTF LU04125 giving GIM37903E during apply check

book

Article ID: 240311

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

Apply check failed with below error assist

 

GIM37903E ** APPLY PROCESSING FAILED FOR SYSMOD LU04125 BECAUSE IT HAS NO APPLICABLE ++VER MCS.
GIM24801S ** NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY COMMAND.
GIM20501I    APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.

Environment

Release : 16.0

Component :

Resolution

The APPLY job will return this error when attempting to apply to the wrong FMID.    LU04125 is for SYSVIEW release 15.0.    

For release 16.0, LU05614 should be applied instead.

  

 

Additional Information

Note:  Security advisories are specific to the release for which they are written.