Users observe latency when updating job statuses. Attempting to restart the AutoSys Application Server fails, and the application log displays the following error sequence:
CAUAJM_E_18416 Event Server: <name of database> Failed Query: <select str_val from ujo_alamode where type='BINARY_VERSION'>
CAUAJM_E_18402 ORA-12571: TNS:packet writer failure
CAUAJM_E_18400 An error has occurred while interfacing with ORACLE.
CAUAJM_E_18401 Function <doExecute> invoked from <execute> failed <902>
CAUAJM_E_40213 AutoSys Application server does not start as the AEDB version does not match with the product version.
CAUAJM_I_30004 AutoSys Application Server shutdown complete.
Product: CA Workload Automation AE (AutoSys)
Release: 12.1 and higher
Database: Oracle
The Oracle client on the Application Server machine is encountering network connectivity failures when communicating with the AutoSys database (AEDB). Hostname resolution issues typically trigger ORA-12571: TNS:packet writer failure, preventing the Application Server from verifying the database schema version.
Update the Oracle TNS configuration to use the database server's direct IP address instead of its hostname:
On the AutoSys Application Server host, locate the tnsnames.ora file (typically in $ORACLE_HOME/network/admin or defined by %TNS_ADMIN%).
Open tnsnames.ora in a text editor.
Locate the entry for the affected Oracle Event Server (ORCL1 / ORCL2).
Update the HOST parameter in the connection string to use the static IP address of the Oracle database server instead of the hostname:
(ADDRESS = (PROTOCOL = TCP)(HOST = <Database_IP_Address>)(PORT = <Port>))
Save the file.
Restart the AutoSys Application Server.