Issue/Introduction

When upgrading ITMS or Configuring ITMS it fails with the error:

Log shows the following error:

ConfigureNS - task_Completed(): Configuration Task Configuring services... Failed: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> Altiris.NS.Exceptions.SetIdentityException: Failed in SetServiceCredential setting 'AltirisSupportService' service to use 'UserID\Server'. ---> Altiris.NS.Exceptions.AeXException: Failed to OpenService. Error=80070424.

Environment

ITMS 8.x

Cause

  • Altiris Services are not running
  • You are not logged in with Service Account/AppID and the Symantec Installation Manager is not running as admin.

Resolution

Make sure any operations involving configure type activities, such as upgrades, reconfigurations, or solution installs are run while logged in as the AppID or service account, and SIM needs to be run with right-click and use the 'Run as administrator" option.