Issue/Introduction

We are receiving incidents of severity major when the robots were under maintenance mode window.

Below is the incident alert with description:

Short description: BootAlarm: Computer has been rebooted at 2022.3.27  0:15:07

Description:

event_source: Netcool Ticketing
Summary: BootAlarm: Computer has been rebooted at 2022.3.27  0:15:07

Date: 27/03/2022        Severity: Major
ResourceId: 
TicketGroup: eCP_NEMO        
InstanceSituation: Custom_Nimsoft
Node: 
NodeAlias: fe80::
Agent: EIF Probe on lvpiu9
AlertKey: NIMSOFT:Custom_Nimsoft:BootAlarm: Computer has been rebooted at 2022.3.27  0:15:07:Env=
AlertGroup: Custom_Nimsoft
MonitoringSolution: EventIntegrator

As per the below link, We should not be receiving incidents of severity major during maintenance mode window.

Please assist on this.

https://techdocs.broadcom.com/us/en/ca-enterprise-software/it-operations-management/ca-unified-infrastructure-management-probes/GA/alphabetical-probe-articles/maintenance-mode-maintenance-mode.html

 

Environment

Release : 20.3

Component : UIM MAINTENANCE MODE

Resolution

Follow the below step:-

1. Deactivate nas probe.
2. Deactivate maintenance_mode probe.
3. Drop the below table.

MAINTENANCE_WINDOW

4. Activate maintenance_mode probe (The maintenance_window table will be recreated)
5. Activate nas probe.