Watch using text strings and thresholds getting User Defined error
search cancel

Watch using text strings and thresholds getting User Defined error

book

Article ID: 238184

calendar_today

Updated On:

Products

Spectrum

Issue/Introduction

Using the MIB FORTIGATE-MIB customer would like to create a watch for the following OIDs

  • latency - fgVWLHealthCheckLinkLatency - .1.3.6.1.4.1.12356.101.4.9.2.1.5
  • jitter - fgVWLHealthCheckLinkJitter - .1.3.6.1.4.1.12356.101.4.9.2.1.6
  • packet loss - fgVWLHealthCheckLinkPacketLoss - .1.3.6.1.4.1.12356.101.4.9.2.1.9

which are already mapped into Spectrum as text string attributes but he is getting:

 

Environment

Release : 22.2.x, 23.3.x

Component : Spectrum Alarm

Cause

The watch was defined as follows:

 

Resolution

To prevent the "user defined error" as the attribute is defined as text string the value should be specified around double quotes.