Message ESP7044I in the JES log indicating the wrong restart FROM step.
search cancel

Message ESP7044I in the JES log indicating the wrong restart FROM step.

book

Article ID: 23810

calendar_today

Updated On:

Products

ESP Workload Automation

Issue/Introduction

ESP Workload Automation Restart Option EE (Encore) restarted the job correctly, but message ESP7044I in the JES log shows the wrong restart FROM step.

 

Environment

Release: All Releases
Component:  ESP Workload Automation
                      ESP Workload Automation Restart Option EE 

Resolution

Message ESP7040I describes the restart intent. Showing the step that was requested by a user or initially chosen by Encore before any adjustments.
Further analysis may cause the inclusion of other steps in order to recreate data sets or to avoid starting at a non-restartable step. These adjustments are detailed in the printed restart summary in the SYSPRINT of the Encore step and in the restart analysis panels in GUI and ISPF.