ALERT: Some images may not load properly within the Knowledge Base Article. If you see a broken image, please right-click and select 'Open image in a new tab'. We apologize for this inconvenience.

AS400 agent dies after the following error: U02000102 Error when calling the function 'cmdData', error code '5022'.

book

Article ID: 238096

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Symptoms:

1. Newly installed AS400 agent dies after the following error in the agent log file:

U02000102 Error when calling the function 'cmdData', error code '5022'. 

2. In the joblog, the following message is present:

'Member KEYSTORE for file INI in library UC4 not found.'  However, SSL is not being used.

3. The values in the agent .ini file for keystore are empty:

(AUTHORIZATION)
KEYSTORE=
INITIALPACKAGE=

 

Cause

Defect

Environment

Release : 12.3.8

Component : AUTOMATION ENGINE, AS400 agent

Resolution

The issue is defect, will be fixed in the future.

In the meantime, use the workaround:

1. If keystore is utilized, specify its location.

2. If keystore is not utilized, the following changes in the .ini file will fix the issue:

(AUTHORIZATION)

InitialPackage=

KeyStore=UC4/INI(KEYSTORE)