search cancel

ACF2 support for the REUSASID option

book

Article ID: 237789

calendar_today

Updated On:

Products

ACF2 - z/OS

Issue/Introduction

ACF2 is frequently stopped and restarted on one of our test systems. This causes various system resources related to cross-memory services to be consumed (address space ID numbers, system linkage indexes, etc.), and can result in abends such as an S053-112 abend.

If ACF2 supports the REUSASID option, this might help us, but I can not find any documentation indicating if the option is supported by ACF2. 

Can you advise whether or not the REUSASID option is supported by ACF2?

Environment

Release : 16.0

Component : ACF2 for z/OS

Resolution

ACF2 can be started with REUSASID=YES in DIAGxx and can be used like this : S ACF2,REUSASID=YES