PPM-002 error in AC configuration for Processes probe
search cancel

PPM-002 error in AC configuration for Processes probe

book

Article ID: 237488

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

When accessing the process probe normal configuration there is a window that pops up with error messages as shown on the screenshot below.

The Raw configuration works fine, but there is an issue while accessing the probe configuration GUI interface in adminConsole.




Environment

Release : 20.4

Component : UIM - PPM

Cause

Error Code: PPM-002

Internal Server error: Unexpected/Unknown error occurred

Resolution

Disable IP Validation in the hub.cfg:

- Navigate to the <nimsoft>\hub folder.

- Edit the hub.cfg file

- Change the following parameter: ignore_ip = yes 

- Restart the hub and test