ALERT: Some images may not load properly within the Knowledge Base Article. If you see a broken image, please right-click and select 'Open image in a new tab'. We apologize for this inconvenience.

openstack probe profile in failure state

book

Article ID: 237084

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

Test for the profile works, but then the profile is in a failure state. 

RedHat version of OpenStack rosp16 which is equivalent to OpenStack release Train

Exception occurred while adding Tenants for region[regionOne]. Exception >>ClientResponseException{message=Cannot deserialize instance of `java.lang.String` out of START_OBJECT token

Cause

For 'Train' and subsequent series of Openstack, there are changes made in the SDK (provided by Openstack) resulting in connection issues from the probe. 

Environment

Release : 20.4

Component :

Resolution

Update openstack probe to later than 1.38.