INSUFFICIENT ACCESS AUTHORITY When Creating a Data set with XCOM for z/OS.
search cancel

INSUFFICIENT ACCESS AUTHORITY When Creating a Data set with XCOM for z/OS.

book

Article ID: 23669

calendar_today

Updated On:

Products

XCOM Data Transport - z/OS

Issue/Introduction

INSUFFICIENT ACCESS AUTHORITY When Creating a Data set with CA XCOM for z/OS.  The SYSLOG will have a more detailed message, such as:

ICH408I USER(XCOM ) GROUP(XXXX ) NAME(STC- XCOM ) DATASET NAME VOL(XXXXX) INSUFFICIENT ACCESS AUTHORITY

NOTE: This is an RACF message. The actual error message will vary according to your security package.

 

 

 

Environment

Release: XCOM for z/OS
Component:

Cause

This indicates that the XCOM Started Task did not have sufficient authority to create the data set. When XCOM Data Transport opens a file, the security package uses the access authority granted to the XCOM Data Transport address space rather than to the user.

Resolution

Security must be configured correctly for the XCOM Started Task. The XCOM Data Transport started task needs a security profile that allows the full range of file transfers to be implemented; otherwise, even when the user has authorization to access a data set, a 913 abend code may be generated.

Additional Information

See topic XCOM Security Interfaces in the XCOM for z/OS 12.0 on line documentation.

When XCOM Data Transport opens a file, the security package uses the access authority granted to the XCOM Data Transport address space rather than to the user. Therefore, XCOM Data Transport should be given access authority for all data sets (except for sensitive data sets that will never be needed by XCOM Data Transport users). 913 abends indicate that a user has authorization to access a data set, but the XCOM Data Transport address space does not. In this case, XCOM Data Transport sends an error message to the user.