Endevor CLIST C1SR1400 fails with IKJ56545I error 
search cancel

Endevor CLIST C1SR1400 fails with IKJ56545I error 

book

Article ID: 236068

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

Attempting to run the Footprint Exception Report - 83, using the C1SR1400 CLIST. 

 
It fails with the following messages:
SET &RPTNUM = RPT83                                                       
SET &RPTNUM = RPT83                                                       
IF &STR(&RPT83) ¬= &STR( ) AND &STR(&RPT83) ¬= &STR(_) THEN               
IF / ¬=   AND / ¬= _ THEN                                                 
SET &REPORT = &STR(&REPORT 83)                                            
SET &REPORT =  83                                                         
ERROR OFF                                                                 
ERROR OFF                                                                 
IF &RPT83 NE &STR( ) AND &RPT83 NE &STR(_) THEN                           
IF / NE   AND / NE _ THEN                                                 
IKJ56545I THIS STATEMENT HAS AN EXPRESSION WITH OPERATORS OUT OF SEQUENCE 
***                                                                       

 

Environment

Release : 18.0  18.1

Component : Endevor Software Change Manager

Resolution

This is a known defect and can been resolved by applying the following PTF: 

  • For Endevor V18.0 Apply PTF LU06160 
  • For Endevor V18.1 Apply PTF LU05190