Issue/Introduction

Installed and configured a new UIM probe - VNXE probe - (vnxe_monitor 1.03). I am receiving alarms and inventory in DX but no metrics. I have the probe configured to send metrics

 

Environment

Release : SAAS

Component : CA DOI INSTALLER

Resolution

Added probe to QoS parameters for the OI Connector. https://techdocs.broadcom.com/us/en/ca-enterprise-software/it-operations-management/ca-unified-infrastructure-management-probes/GA/alphabetical-probe-articles/oi-connector-ca-digital-operational-intelligence-gateway/oi-connector-ac-configuration.html#concept.dita_083dc742550d0d1c479d3637522c9cbd6f094e72_EnableAlarmGroupsandQoS