DUAS: Server Engine List fails with Object not found error: 600
search cancel

DUAS: Server Engine List fails with Object not found error: 600

book

Article ID: 235927

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Dollar Universe node is running and uprocs are processing but Server Engines can not be displayed via UVC neither via the command unicheck.

Error displayed in console.

Error from command line:

..\bin>unicheck.bat
Dollar Universe check procedure
 Command : uxlst fnc fnc=* exp

Object not found error
command in error!!

 

This started to occur after a UVMS Migration operation where nodes were unregisted from UVMS A and registered in a UVMS B with this kind of command that contained "OAP=0" for Windows nodes:


unims -register -login admin -pwd XXX -mshost UVMS_SERVER -msport 4184 -host DUAS_SERVER -Xservers "IO=10301,BVS=10306,CDJ=10312,DQM=10316,EEP=10305,GSI=10319,JEE=0,SAP=0,OAP=0"

Environment

Release : 6.x

Component : DOLLAR UNIVERSE

OS: Windows

Cause

When registering a Dollar Universe node to UVMS using the command unims, if you specify the engine OAP on windows, the command succeeds.

But after that, any command related to Engines will fail and engines won't be displayed via Univiewer Console

Engine OAP does not exist on WINDOWS.

Resolution

Workaround: Unregister the node and register it again without OAP engine

Solution:


Update to a fix version listed below or a newer version if available.


Fix version(s): 
Component: Dollar Universe
Dollar Universe 6.10.101 - Planned Release Second Half May 2022