Issue/Introduction

After upgrading Datacom/AD from 14.0 to 15.0 for CSM 6.0 started receiving DB01900I - DATACOM    MSM and CAS9180E - CPU 01CF98 Requires a LMP key to run Prod (  ) in the MSMMUFS startup. In the CAS9180E message, the Product code is displayed as blanks. This message also appears for Common Components and Services (ENF) MUFs that have used DATACOM MSM in the MUF Startup Options.

Environment

Release : 15.0 and higher

Component : Datacom/AD

Resolution

In the MUF Startup Options-- for example, CUSMAC(MUFSTART) for MSM -- change DATACOM    MSM to DATACOM    AD and recycle the MUF. The situation also applies to Common Components and Services (ENF) MUFs that have run with the DATACOM MSM setting, and is corrected by changing to DATACOM AD.