Deliver - ECSA exhaustion, PQEs obtained by RMOASPEP
search cancel

Deliver - ECSA exhaustion, PQEs obtained by RMOASPEP

book

Article ID: 235048

calendar_today

Updated On:

Products

Deliver

Issue/Introduction

An LPAR was lost due to CSA exhaustion. 

Leading up to the problem, there were 123,814 x90 byte areas obtained by RMOASPEP with PQE eyecatchers in them. 

Environment

Release : 14.0

Component : Deliver

Resolution

It was explained that there needed to be fewer execution classes specified in the RMOPARM JOBCLSL=... parameter. 

It was also suggested about placing RMOSTC in a higher dispatching class.