Probe Failure after Upgrading apm_bridge to version 1.06 from 1.04
search cancel

Probe Failure after Upgrading apm_bridge to version 1.06 from 1.04

book

Article ID: 234471

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

Upgrade to  newer version of apm_bridge  led to probe failure, with below error in logs:

ŞŞub 08 16:02:26:362 ERROR [APMInventoryService RUNNING, apm_bridge] Could not read cfg. Exiting
(90) Configuration error, No value found for key resources/0/adminConsoleHost
 at com.nimsoft.nimbus.NimConfig.getValue(NimConfig.java:834)
 

 

 

 

 

Environment

Release : 20.4

Component : UIM - APMGTW 1.0.4

Cause

Missed an upgrade step:

To configure apm_bridge probe v1.06, uimapi 20.33 HF2 or a later version is required.

Resolution

Upgrading Umapi to version 20.33HF2, resolved the problem.