Communication Link Down alarm without detailed interface information, not seeing the LINK DOWN trap
search cancel

Communication Link Down alarm without detailed interface information, not seeing the LINK DOWN trap

book

Article ID: 234265

calendar_today

Updated On:

Products

CA Spectrum DX NetOps

Issue/Introduction

We are seeing a LINK UP  Enterprise: 1.3.6.1.4.1.9.9.276  trap after a LINK DOWN  which has interface information, but the LINK DOWN trap does not.

We are using SDC-TrapX

 

 

Environment

Release : 21.2

Component : Spectrum Alarm & Event Management

Cause

The device is sending two OID for LINK DOWN.   Enterprise: 1.3.6.1.4.1.9.9.276, and Enterprise: 1.3.6.1.6.3.1.1.5.3.

In checking TCP dump we are seeing both trap types coming in from the device. 

Only Enterprise: 1.3.6.1.4.1.9.9.276 shows interface information. 

Resolution

TrapX.config is filtering out Enterprise: 1.3.6.1.4.1.9.9.276.0.1 so it is not making over to the SpectroSERVER to map to any event. 

Additional Information

If you are not seeing the trap as expected, verify the following: 

- run tcpdump to confirm the incoming trap

- if using TrapX - double check your trapX.config filters!