GIM23911E ** LINK-EDIT PROCESSING FOR PTF LU02001
search cancel

GIM23911E ** LINK-EDIT PROCESSING FOR PTF LU02001

book

Article ID: 233919

calendar_today

Updated On:

Products

Easytrieve Report Generator

Issue/Introduction

Experiencing the following errors when doing an APPLY CHECK for PTF LU02001:

GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD LU02001 FAILED FOR MODULE EZBOMB IN LMOD EZTCOM IN THE CBAALOAD LIBRARY.

             THE RETURN CODE (12) EXCEEDED THE ALLOWABLE VALUE. DATE 22.034 - TIME 11:22:23 - SEQUENCE NUMBER 000005 -
             SYSPRINT FILE SMP00003.
GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD LU02001 FAILED FOR MODULE EZISSEQ IN LMOD EZTCOM IN THE CBAALOAD LIBRARY.
             THE RETURN CODE (12) EXCEEDED THE ALLOWABLE VALUE. DATE 22.034 - TIME 11:22:23 - SEQUENCE NUMBER 000005 -

             SYSPRINT FILE SMP00003.

How may these link-edit processing errors be resolved?

Environment

EASYTRIEVE REPORT GEN, release 11.6

Resolution

The libraries, ABAALOAD and CBAALOAD, need to be PDS/e libraries and they are allocated as such.

But the following error are also reported:

IEW2322I 1220  299    NAME EZTCOM(R)                         MAX ACCEPTABLE RC=04
IEW2756S D609 SPACE IS NOT AVAILABLE ON DIRECT ACCESS STORAGE TO SAVE MEMBER EZTCOM. 
 
This is equivalent to a B37-04 abend.  There is not enough space in the load library.
 
For ours, we have 6144 specified for the block size with (19 primary cylinders used and 1 secondary extent cylinders used.
 
The resolution is to move the dataset to another volume with more space and the PTFs then applied successfully.