Issue/Introduction

I am applying View 14.0 PTF LU00151, but am having problems with the link-edit, receiving this error:

  IEW2307E 1032 CURRENT INPUT MODULE NOT INCLUDED BECAUSE OF INVALID DATA

Could you check the output, please?

 

Environment

Release : 14.0

Component :

Resolution

This message appeared in the SMP/E output below the PTF LU00151:

  IEW2307E 1032 CURRENT INPUT MODULE NOT INCLUDED BECAUSE OF INVALID DATA.

It was determined that LU00151 had not been RECEIVEd in its entirety. 

As the PTF had only been RECEIVEd, the client was asked to an SMP/E REJECT on LU00151, then to do a new download of the PTF from the Support Site, then to do the RECEIVE of it again.

Following that, the APPLY of the PTF occurred without errors.