Using ACF2 ISPF screens to maintain DFP Compiled DATASET profile records
search cancel

Using ACF2 ISPF screens to maintain DFP Compiled DATASET profile records

book

Article ID: 233287

calendar_today

Updated On:

Products

ACF2 - z/OS

Issue/Introduction

Trying to use the ACF2 ISPF screens to maintain one of these type of profiles for dataset encryption.

 

 

Using this option, what should be specified for the RTYPE field.

-------------------- PROFILE COMPILED RECORD PROCESSOR -----------------
COMMAND===>                                                       
                                                                        
SPECIFY DATASET/MEMBER NAME FOR COMPILED RECORD.  THE MEMBER NAME IS    
USED AS THE RECORD KEY FOR RETRIEVAL.  IF THE RECORD EXISTS, IT WILL BE 
PLACED IN THIS DATASET FOR EDITING.  IF THE RECORD DOES NOT EXIST, AN   
EMPTY DATASET MEMBER WILL BE CREATED FOR EDITING.                       
                                                                        
CA ACF2 PROFILE PREFIX NAME (MEMBER NAME):                     
   NAME   ===>_<rulekey>            
   RTYPE ===>                                (for SECLABEL and SDB2 only)                   
                                                                        
ISPF LIBRARY DATA SET (DO NOT INCLUDE MEMBER NAME):                     
   PROJECT===> <hlq>                                               
   LIBRARY ===> <library>                                               
   TYPE       ===> <type>                                               
                                                                        
OTHER PARTITIONED DATA SET (DO NOT INCLUDE MEMBER NAME):                
   DATA SET NAME  ===> <dsn>   
                                                                        
SPECIFY YES ALONG WITH PROFILE PREFIX NAME ABOVE TO DELETE AN EXISTING  
RECORD.                                                                 
DELETE PROFILE RECORD OPTION===> NO                          YES OR NO                     

Environment

Release : 16.0

Component :

Resolution

The RTYPE field in the PROFILE COMPILED RECORD PROCESSOR panel is only used for
MLS SECLABEL 'Compiled Profile Records' or 'SDB2 Compiled Profile Records' records and
should be left blank for any other type of compiled profile record.
It is not used for DFP DATASET Compiled Records.