Issue/Introduction

The following error is encountered when trying to install the CA Harvest Web Interface (harweb)

 

No X11 DISPLAY variable was set, but this program performed an operation which requires it.
        at java.awt.GraphicsEnvironment.checkHeadless(GraphicsEnvironment.java:217)
        at java.awt.Window.<init>(Window.java:547)
        at java.awt.Frame.<init>(Frame.java:431)
        at java.awt.Frame.<init>(Frame.java:396)
        at javax.swing.JFrame.<init>(JFrame.java:200)
        at com.ca.harvest.wizard.harwebinstall.EULADialog.<init>(Unknown Source)
        at com.ca.harvest.wizard.harwebinstall.HarwebInstall.main(Unknown Source)

Environment

Release : 13.0.3, 14.0

Component : CA HARVEST SCM GUI/Harweb

Cause

The system on which the SCM Web Interface (harweb) is intalled does not have a graphic interface.

Resolution

The solution would be installing Harweb in unattended mode.