Where do you configure ecometer in 20.4, 23.4 (with example device)
Release : 20.4, 23.4
Component : UIM - ECOMETER_ADMIN
1. Deactivate wasp probe on Operator Console machine
2. Deploy to your Operator Console machine
20.4 - 23.4 pre CU2
ecometer_admin 5.11
ecometer_efficiencyreport 5.01
webservices_rest 20.4x, 23.4.x (version that correlates to the CU pack installed)
23.4 CU2+
ecometer_admin 5.13
---------- need to check this -------- ecometer_efficiencyreport (5.01)
webservices_rest 23.4.x (version that correlates to the CU pack installed)
3. Activate wasp probe on Operator Console machine
4. Deploy to your robot that will contain the ecometer probe
20.4 - 23.4 pre CU2
ecometer_monitor 5.02
ecometer_3rdpartylibs 5.02
23.4 CU2+
ecometer_monitor 5.13
ecometer_3rdpartylibs 5.13
5. Deactive/Activate the ecometer_monitor probe (to have the 3rd party libraries applied)
6. Once wasp has restarted on the Operator Console machine open the ecometer_admin via Settings > Ecometer Admin
7. Grab the attached resources file which can be imported into the poller
8. Click on Administrator and select to import the file
9. Select APC_UPS and import (as an example)
10. Next you will want to add a device
11. Find a device in that has sysobjectid that starts with 1.3.6.1.4.1.318, and start it up under public
12. Once the device is added select the device and then click the Restart polling button |>
13. Once the status goes green > you can then open up the ecometer_monitor probe in AC. You should now see your device listed where you can turn on data and alarms:
Manage device templates - Manage calculations
ecometer installation deployment and best practices
Note: Prerequisite: The minimum DX UIM Version is 23.4 CU2 for ecometer_monitor v5.13.