Unable to Access NFA console from CA PC
Error:
The webpage at https://10.10.1.1/RA/default.aspx?pg=3000&mn=101&SsoToken=wK4zhFcxXPSIoXMzrPriHdY5EQgeyk_okOtk-kU3WZ-k-lAOS_chrDXLFBbIi9_D might be temporarily down or it may have moved permanently to a new web address.
ERR_CONNECTION_ABORTED
Release : 20.2
Component : PERFORMANCE MANAGEMENT INTEGRATIONS
In correct configuration of Web Console Port
Edit the Network Flow Analysis data source
Configure WebConsole with the correct host and port, if it is same as Data source check Same as data source
If it is different then uncheck and enter the hostname and port.
Save the configuration
Now try to access the console and check
If the Web Console is on a different system than the data source, clear the Same as data source check box, and then specify another Host Name and Port for the data source console.
https://techdocs.broadcom.com/us/en/ca-enterprise-software/it-operations-management/performance-management/20-2/administrating/manage-data-sources/configure-a-data-source.html