After applying PTF LU02209 the following error message was seen in OPSLOG:
OPT7910W STATEMAN REQUEST RULE SSMTMOMA NOT FOUND. NO ACTION TAKEN
OPS7910W STATEMAN REQUEST RULE SSMTMOMA NOT FOUND. NO ACTION TAKEN
OPM7910W STATEMAN REQUEST RULE SSMTMOMA NOT FOUND. NO ACTION TAKEN
Release : 14.0
Component : OPS/MVS
SSM version: SSMV3
PTF LU02209 includes a new rule, SSMTMOMA. If running SSMV3 and the rule has not been copied from the hlq.CCLXRULS target library to a production ruleset, the error occurs.
1. Copy member SSMTMOMA from the hlq.CCLXRULS target library to a production ruleset.
2. Ensure ISPF statistics have been reset for the SSMTMOMA member per the HOLD ACTION instructions included in LU02209:
This PTF installs updated AOF rule(s) into SMP/E Target library
CCLXRULS with no ISPF statistics. You will not be able to auto-enable
the updated rule(s) until you reset their ISPF statistics. You can use
ISPF option 3.5 to manually reset the ISPF statistics for the updated
rule(s). You can use ISPF option 3.3 to manually copy the updated
rule(s) to your deployed ruleset(s).
3. Enable and then auto-enable the SSMTMOMA rule.
The error message should now no longer occur.