Current refresh rate for alarm view is 5 minutes. There is an issue when multiple operators are using DX for alarm views there is little synchronization between displays due to 5 minute refresh.
Alarm view needs to update to near real time
Release : SAAS
Component : CA DOI NOTIFICATIONS
Alarm table refresh interval is configured by default to 5 mins for all tenants. This is configured in admin-ui.
Resolution – Modified logic to have this configuration changed per tenant level. ALARM_REFRESH_INTERVAL environment variable can be used to change refresh interval per tenant. This configuration is available in doi-readserver.
Modified logic to have this configuration changed per tenant level. ALARM_REFRESH_INTERVAL environment variable can be used to change refresh interval per tenant. This configuration is available in doi-readserver.
Ex : ALARM_REFRESH_INTERVAL=DEFAULT:5,<TENANT_ID>:<Value>
60 second screen refresh on the alarm view was enabled and solved the issue.