Screen Refresh rate on alarm view
search cancel

Screen Refresh rate on alarm view

book

Article ID: 231048

calendar_today

Updated On:

Products

DX OI SaaS

Issue/Introduction

Current refresh rate for alarm view is 5 minutes. There is an issue when multiple operators are using DX for alarm views there is little synchronization between displays due to 5 minute refresh.

Alarm view needs to update to near real time

Environment

Release : SAAS

Component : CA DOI NOTIFICATIONS

Cause

 Alarm table refresh interval is configured by default to 5 mins for all tenants. This is configured in admin-ui. 
Resolution – Modified logic to have this configuration changed per tenant level. ALARM_REFRESH_INTERVAL environment variable can be used to change refresh interval per tenant. This configuration is available in doi-readserver. 

Resolution

Modified logic to have this configuration changed per tenant level. ALARM_REFRESH_INTERVAL environment variable can be used to change refresh interval per tenant. This configuration is available in doi-readserver. 

 Ex : ALARM_REFRESH_INTERVAL=DEFAULT:5,<TENANT_ID>:<Value>

60 second screen refresh on the alarm view was enabled and solved the issue.