HTTP 500 error message when worker process requests a recycle.
search cancel

HTTP 500 error message when worker process requests a recycle.

book

Article ID: 23070

calendar_today

Updated On:

Products

Network Flow Analysis

Issue/Introduction

Issue/Problem/Symptoms: 

Changes to default properties of the applications pools recycling tab may cause a HTTP 500 error message when loading web pages on ReporterAnalyzer.

 

 

Environment

Release:
Component: NQRPTA

Cause

Cause: 

A worker process is a windows process (w3wp.exe) that runs Web applications, and is responsible for handling requests sent to a Web Server for a specific application pool. A HTTP 500 page may be displayed on ReporterAnalyzer if the default settings for the Application Pools - Recycling Tab is changed. This tab is used to administrate the recycling of worker processes and the only option that should be checked is "Recycle worker processes (in minutes): 1740". Changes to this tab will usually result in the following event log error message: "worker process with process id of 'xxxx' serving application pool 'yyyy' has requested a recycle because ...".

Resolution

Resolution/Workaround:

To restore the recycling tab default setting, please follow the steps below:

  • Open a windows command prompt.
  • Type inetmgr.
  • Click the plus sign on the computer name and expand the Application Pools folder.
  • Right click the affected application pool, if AppPoolName is ReporterAnalyzerWebSite then right click on it.
  • Select "Properties".
  • Under the Recycling tab, make sure the only option selected is "Recycle worker processes (in minutes): 1740".
  • Restart the IIS services by typing iisreset on the Windows command prompt.