We can add firewall juniper SRX 1150 series using SNMP v2 in SNMP collector probe.
However, when we try to use snmpv3, it always failed. Below are the provided snmp trace from juniper SRX 1150. It seems it try to use sysobj which are not exist in juniper:
snmpd[33c37cf] <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
SNMP Target: ip address PDU request id: id number , rsp(us): 235
snmpd[33c4195] >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
snmpd[33c4195] >>> Get-Request
snmpd[33c4195] >>> Source: IP address
snmpd[33c4195] >>> Destination: IP adrress
snmpd[33c4195] >>> Version: SNMPv3
snmpd[33c4195] >>> Security Parameters:
snmpd[33c4195] >>> SecModel: USM
snmpd[33c4195] >>> EngId: hex id number
snmpd[33c4195] >>> User: user name
snmpd[33c4195] >>> EngBoots: 1 EngTime: 72371
snmpd[33c4195] >>> Request_id: mrequestid no in hex
snmpd[33c4195] >>> Error: status=0 / vb_index=50
snmpd[33c4195] >>> OID : sysObjectID.0
snmpd[33c4195] >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
snmpd[33c4195] <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
snmpd[33c4195] <<< Get-Response
snmpd[33c4195] <<< Source: ipaddress
snmpd[33c4195] <<< Destination: ipaddress
snmpd[33c4195] <<< Version: SNMPv3
snmpd[33c4195] <<< Security Parameters:
snmpd[33c4195] <<< SecModel: USM
snmpd[33c4195] <<< EngId: hex id
snmpd[33c4195] <<< User:username
snmpd[33c4195] <<< EngBoots: 1 EngTime: 72371
snmpd[33c4195] <<< Request_id: id number in hex code
snmpd[33c4195] <<< Error: status=0 / vb_index=0
snmpd[33c4195] <<< OID : sysObjectID.0
snmpd[33c4195] <<< type : NoSuchObj
snmpd[33c4195] <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
Release : 20.3
Component : UIM - SNMPCOLLECTOR
Checked in https://devicesupport.broadcom.com and found this device is not listed . So this device is not supported .
To get the device certified, follow this process:
https://knowledge.broadcom.com/external/article/9900/uim-snmpcollector-device-certification.html