Issue/Introduction

 After applying maintenance the following message was in the Xmanager Log:

GEN0932 Parmlib Reader failed for product: PDA - CONDITION_SQL_ERROR

*** THE FOLLOWING MESSAGES WERE ISSUED DURING PARMLIB PROCESSING:
:SETUPN1    The XMAN connection will use XMANID(2109)
:PDA        Informational message that one or more parm keywords were not found.
:           Return code set minimally to 4.  Parmlib member possibly from
:           previous release and has not been updated.  This is not required to
:           run PDA as it will use defaults but is highly recommended.  Use the
:           on-line Edit Parmlib Member facility, option E.EP or EP from the CA
:           main menu, to update the PDA      parmlib member.  First keyword not
:           found was CONDITION_SQL_ERROR
 *** END PARMLIB MESSAGES

Note: This is just an informational message and will not cause any problem.

Environment

Release : 20.0

Component : Analyzer Common Services

Resolution

This parameter was added by PTF LU01625 in June 2021. 

The PTF states:

After this PTF is applied, add the following parameter to the PDA parmlib member to specify a custom RC code for SQL errors:
 
        CONDITION_SQL_ERROR(RR)
 
The RR value is an integer (4-4095) that specifies the RC code
to use when an SQL error is encountered.