Login to cabi bundled flashing screen. Constant reloading. Selecting dashboards or reports shows Data Access Error. This is running cabi and OC http.
On the CABI robot (note that this is not performed nor valid on cabi v8.0+):
Deactivate the cabi probe.
<CookieProcessor class="org.apache.tomcat.util.http.Rfc6265CookieProcessor" sameSiteCookies="Lax" />
4. Activate the cabi probe.
5. Activate the wasp probe
On the Operator Console robot:
Modify nimsoft/probes/service/wasp/webapps/cabi/META-INF/context.xml with
<CookieProcessor class="org.apache.tomcat.util.http.Rfc6265CookieProcessor" sameSiteCookies="Lax" />
2. Activate the wasp probe
When connecting to the OC interface make sure to connect using the following url syntax/format:
http://<URLwithMatchingSubdomainAndDomain>:<port>/operatorconsole_portlet
Note: When using HTTP it is required to use the full domain name (not IP address) when logging into OC, and for the connection to the cabi server. Same site functionality in browsers has been slowly removed, to where it would allow to ignore the errors related to a same site connection issue, to now where they no longer allow the ability to get around it.