Upgrading SYSVIEW on an LPAR, all seems fine for most users, however a CICS system programmer cannot switch between CICS regions.
Normally issuing a CICSLIST, selecting a CICS region and using CTRANS, CTAS and then getting the information for a single CICS region.
Trying to switch to a different CICS region and getting stuck on the first CICS region selected.
Deleting the GSVXPROF ISPF profile and the SYSVIEW profile from the PROFLIB dataset doesn't resolve this problem.
SYSVIEW 15.0 & 16.0
From the CTRANS display, the display shows for OPTIONS:
Options INDEX SYSTEM MEMBER UPDATE SORT OPTIONS INFO
This is far too many OPTIONS and this is not correct.
The PROFILE for that User needs to be deleted from the PROFLIB dataset and then create a new profile for this USER using the PROFILE CREATE,U1,U2 command.
CREATE,u1,u2 | Creates a new profile for user ID u1 by copying the
| profile of u2. If a profile for u1 exists, then it is
| overlaid. Only administrators can create profiles for
| other users.
The problem is actually in the user's 15.0 profile which is being used to build the new profile.
This occurred when having a PROFILE DSN in the SCFG member.
It will just create a new PROFLIB (r16.0) member using the PROFILE (r15.0) member as input.