ILM warning message about non existing login object.
search cancel

ILM warning message about non existing login object.

book

Article ID: 228376

calendar_today

Updated On:

Products

CA Automic One Automation

Issue/Introduction

During the drop of ILM partitions the following messages are shown:

20211024/133505.049 - U00005353 ILM: Processing after system stop was called with option 'DY5' .
20211024/133505.050 - U00005309 The given login object 'LOGIN_OBJECT' does not exist or does not contain an entry of type DB. The user cannot be changed.
20211024/133505.113 - U00005344 ILM: Skip checking as partition '5' has successfully been checked before.

20211024/133913.125 - U00005353 ILM: Processing after system stop was called with option 'DY6' .
20211024/133913.126 - U00005309 The given login object 'LOGIN_OBJECT' does not exist or does not contain an entry of type DB. The user cannot be changed.
20211024/133913.181 - U00005344 ILM: Skip checking as partition '6' has successfully been checked before.

20211024/134134.240 - U00005353 ILM: Processing after system stop was called with option 'DY7' .
20211024/134134.241 - U00005309 The given login object 'LOGIN_OBJECT' does not exist or does not contain an entry of type DB. The user cannot be changed.
20211024/134134.298 - U00005344 ILM: Skip checking as partition '7' has successfully been checked before.

Environment

Release : 12.3

Component : AUTOMATION ENGINE

Cause

Configuration.

Resolution

The row containing the login object information (LOGIN) can be removed from the variable UC_ILM_SETTINGS in client 0 since it is not in use during this action. The database user from the ODBC connection string is also performing the ILM actions.