Processes probe on Solaris 10 SPARC cannot be launched. I receive a Communication Error message. "communication error 80040402".
Release : Processes probe Processes 4.70T1 and 4.80
Component : UIM - PROCESSES
Hardcoded GUI timeout generates this error after 45 seconds if the processes are not loaded in time.
To resolve this issue:
1. Download the 2 files attached:
conf_processes.exe
conf_processes_4.80.exe
2. In the machine where IM is running, browse to:
C:\Users\Administrator\AppData\Local\Temp\2\util
3. Delete the files contained in this folder called:
conf_processes.exe
conf_processes_4.80.exe
4. Copy the 2 files attached to this KB into that folder.
5. The new files contain a higher timeout and this will resolve the issue.
A new version of the probe (Hotfix) will include the increased timeout GUI exe's by default.